50 Using appropriately rated lifting slings on Daniel Ultrasonic Meters
Section 3: Installation Reference, Installation, and Operations Manual
August 2014 3-9000-743 Rev U
Once the lifting operation is complete, reattach and secure the electronics cable to J3
on the Acquisition Module, return the electronics enclosure to its original position,
replace the bolts, and secure the enclosure in place. Lifting the meter with the upper
enclosure installed but with out the bolts installed, may cause the electronics to fall and
cause personal injury or electronics damage.
Figure 3-6 Incorrect sling attachment
7. NEVER apply shock loads to the meter. Always lift the meter gradually. If shock loading
ever occurs, the slings must be inspected per manufacturer's procedures prior to being
placed in any further service.